3D IR-Drop simulation of a complex multilayer PCB

This article deals with the simulation of the voltage drop for complex power delivery networks. Such a simulation is useful to the design engineer in order to ensure the power integrity. With the help of the CST EM STUDIO™ (CST EMS) stationary current solver the 3D distribution of the potential and current density on all layers of a complex PCB board can be easily determined.  The static IR-Drop simulation is the primary focus in this article but a dynamic simulation would also be possible in CST MICROWAVE STUDIO®. Before we can start to setup the simulation the PCB board needs to be input.

The multilayer GERBER import was used which is a very general import option that can be linked to all layout/routing tools that can export in GERBER format.


3D model of the imported PCB (copper only). The z-axis was scaled for demonstration purpose to show the details within such a board.
Figure 1: 3D model of the imported PCB (copper only). The z-axis was scaled for demonstration purpose to show the details within such a board.

After the import the material and sources can be defined. In this model input was defined as a fixed potential and all the 96 output ports prescribed a specific current. In reality this represents the current consumed by the ASIC on top of the pins. The option is available to either setup one specific case of input/output or simulate the conductance matrix. This matrix could be used in a circuit simulation in CST DESIGN STUDIO™ (CST DS) to  very quickly obtain specific voltage and current information for different situations. 


Model setup on the top layer. The power source is shown in red. We used a fixed potential for this source. The 96 output pins are shown in blue and all setup with the same current consumption.
Figure 2: Model setup on the top layer. The power source is shown in red. We used a fixed potential for this source. The 96 output pins are shown in blue and all setup with the same current consumption.

For each simulation the voltage and current at the port is monitored. This allows the voltage drop at a given port to be easily verified. In addition to the scalar potential distribution, CST EMS calculates the electric and current density as vector fields. This helps to decide if the design is reliable or not.

 


Voltage drop on top layer. Input and output ports are located on this layer.
Figure 3: Voltage drop on top layer. Input and output ports are located on this layer.


Voltage drop on ground layer. The source current is routed through vias to this layer from the source to the sink.
Figure 4: Voltage drop on ground layer. The source current is routed through vias to this layer from the source to the sink.

This article has briefly demonstrated the use of CST EMS’s stationary current solver for static IR-Drop simulations. Due to the robust meshing technique and the fast solvers, very complex PCBs can be simulated without any approximations in 3D. 

This model was provided courtesy of Umberto Gatti,  Nokia Siemens Networks S.p.A.,  Cinisello Balsamo, Italy.

 


CST Article "3D IR-Drop simulation of a complex multilayer PCB"
last modified 30. Sep 2011 6:52
printed 10. Feb 2012 6:54, Article ID 323
URL:

All rights reserved.
Without prior written permission of CST, no part of this publication may be reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.

Other Articles

3D EM simulation of mixed analog / digital multilayer PCB

3D EM simulation of mixed analog / digital multilayer PCB
This article describes the use of CST CST MICROWAVE STUDIO® (CST MWS) to solve a coupling problem in a mixed analog – digital multilayer PCB card. Courtesy and permission of Alvarion, Ltd, Tel-Aviv, Israel. This example gives an insight into the usefulness of simulation of problems that cannot be investigated easily via measurement and allows the engineer to carry out virtual experiments as demonstrated here with the cutting of the signal trace. Experiments may show the presence of a particular problem but not its location. Even when the problem has been located, further prototypes and experiments are costly and time-consuming. CST MWS offers a straightforward workflow for the set-up and simulation of such problems via its advanced user-interface and EDA interfaces. Read full article..

Photonic Crystal Simulation

Photonic Crystal Simulation
The paper demonstrates the possibilitiy to model photonic cyrystals using CST MICROWAVE STUDIO®. A one dimensional periodic band-gap structure is simulated using the Transient Solver. Read full article..

Calculation of Cogging Torque in a Surface Permanent Magnet Motor

Calculation of Cogging Torque in a Surface Permanent Magnet Motor
CST EM STUDIO® is used to calculate the cogging torque in a 4-pole Surface Permanent Magnet Motor (PMSM). For such a calculation a parametric sweep is performed to determine the torque on the rotor at angular intervals. Only the permanent magnets are required in the model. The stator winding excitation is not necessary for this calculation and is hence omitted in this model. Read full article..

CST PARTICLE STUDIO™ Simulation of a Depressed Collector

CST PARTICLE STUDIO™ Simulation of a Depressed Collector
A multi-stage depressed collector for the "Rijnhuizen" Fusion Free-Electron Maser (FEM) is simulated with CST PARTICLE STUDIO™. The results are reproduced with permission of Pulsar Physics. See also M.J. de Loos, S.B. van der Geer, Pulsar Physics, Nucl. Instr. and Meth. in Phys. Res. B, Vol 139, 1997. Read full article..

3D Non-linear Transient Simulation of an SF6 550 kV 3-Phase Gas Insulated Bus

3D Non-linear Transient Simulation of an SF6 550 kV 3-Phase Gas Insulated Bus
The combination of non-linear materials and eddy currents leads to a problem which cannot be solved with a steady-state eddy current solver. A transient solver is required and and inherently includes the feature that arbitrary time signals can be used for the excitation. The CST EM STUDIO® (CST EMS) transient solver allows such a simulation to be carried out. In this case, a Gas insulated Bus under short circuit conditions is investigated. The forces and losses on the bus bars can be calculated as a function of time. Read full article..

Back