Microwave Plasma Sources
Low-temperature, non-equilibrium plasmas form the basis of a growing variety of plasma related processes such as surface modifications, sterilization, etching and thin film deposition. Plasma sources are a crucial tool in many industrial process steps, for example during the production of integrated circuits. The demand for high-density plasmas over a wide pressure range has stimulated the development and use of microwave plasma sources over the last few years. The Finite Integration Technique (FIT) used in the 3D ECAD simulation package MAFIA has proven to be a powerful tool for the modelling of those complex microwave systems like the SLAN family. CST MICROWAVE STUDIO® is also able to consider the plasma as a dispersive material.
The SLAN family and other plasma sources have been developed at the Microstructure Research Centre (fmt) and are marketed by JE PlasmaConsult GmbH.
Figure 1: Cross section of the microwave plasma source mSLAN, the smallest member of the SLAN family.
The SLAN family consists of four different plasma sources: Mikro-SLAN (4 cm quartz tube diameter), SLAN I (16 cm quartz tube diameter), SLAN II (60 cm quartz tube diameter), and a linear SLAN (approx. 1 m long). The sources are used for the modification of surfaces (scratch resistent layers, improvement of the biocompatibility, improvement of colour adhesion, etc.), creation of hard diamond like carbon surfaces or for the cracking of harmful gases.
Figure 2: Electrical field distribution in the microwave plasma source Mikro-SLAN, the smallest member of the SLAN family.
The left picture shows the distribution of excited oxygen radicals (O*), measured by Laser Induced Fluorescence Spectrometry (LIF) in the inner cylinder of a SLAN I. The electric field distribution calculated in Frequency Domain, for a lossy plasma with similar parameters to those used in the experiment, is very close to the measured ion distribution (right picture).
Figure 3:
Left picture: Simulated electrical field distribution in the inner cylinder of the SLAN I for an O2 plasma with a real part of the permittivity of -1.7 and a conductivity of 0.017 S/m (assumed plasma parameters: ni=2x10e11 cm-3, p=60 Pa, Te=2eV, n_en=7.15x10e8s-1).
Right picture: CCD picture of O2 plasma at 20 Pa, 2000 W microwave power, f=2.45 GHz. Spatial distribution of O*, 845 nm line.
Figure 4: By shifting the shorting plunger of the Micro-SLAN...
The impedance of SLAN plasma sources can be matched by moving the coupling antenna and the shorting plunger. The latter causes a rotation of the field in the ring shaped resonator. The rotation has been simulated using the transient solver. The fields behave in exactly the same way as in the experiment (Figure 4 and 5).
Figure 5: Field rotation in the circular resonator can be achieved and hence the impedance of the plasma source matched to the impedance of the feeding system.
By using the Eigenmode Solver, the homogeneity of the field distribution in the ring shaped resonator of the SLAN I has been improved (Figure 6). This is reflected in the measurement of the plasma density (Figure 7) .
Figure 6: Electric field strength (f=2.45 GHz) for a cross section of the inner cylinder in the basic SLAN I (left picture) and the optimised SLAN I (right picture).
Figure 7:
Relative azimuthal electron density distribution in the basic SLAN I (yellow stars) and in the optimized SLAN I (green stars). Plasma parameters: Argon, 50 Pa, 550 W microwave power at 2.45 GHz. Measured 6 cm downstream, 2 cm from the inner quartz wall with a double Langmuir probe. The maximum measured absolute density amounts to ne=6x10e11 cm-3.
The simulations allowed:
- a better understanding of the microwave coupling into the plasma chamber
- an optimisation of the plasma homogeneity
- an impedance matching of the source.
CST Article "Microwave Plasma Sources"
last modified 10. Mar 2010 8:20
printed 10. Mar 2010 8:20, Article ID 124
URL:
All rights reserved.
Without prior written permission of CST, no part of this publication may be
reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.
Article ID: 124
Last modified: 10. Mar 2010 8:20
Other Articles
This article examines the modelling of lightning strikes using CST MICROWAVE STUDIO® (CST MWS). The surface current distribution due to a double-exponential form lightning strike on the nose of an airplane is calculated by way of example.
Read full article..
This structure for mobile communication in LTCC technology combines a diplexer for the GSM and DCS frequency bands with a low pass filter for each band.
Read full article..
This paper presents the excellent correlation of measurement results to the numerical calculations of a SATIMO dual-ridge horn antenna which include the directivity, boresight gain, and return loss vs. frequency. The structure is electrically large which lends itself, as a result of its efficient memory utilisation, to the CST MICROWAVE STUDIO® (CST MWS) Time Domain Solver. Broadband, high resolution gain results can be obtained within a single run with as many as 100 farfield monitors being defined.
The results are presented with the courtesy and permission of SATIMO, Italy.
Read full article..
The article presents an antenna-based approach to near-field imaging and spectroscopy, which can be used for both continuous-wave and pulsed broadband electromagnetic radiation from microwave to terahertz frequencies. CST MICROWAVE STUDIO® (CST MWS) was used to perform the simulations.
Read full article..
The example design is a classic hairpin filter with a bandwidth of 3.6 to 4.3 GHz. The hairpin filter was designed for a return loss better than -20dB across the band.
CST DESIGN STUDIO™ was used to design and tune the filter, the resulting layout was then verfied with the 3D- EM simulation software CST MICROWAVE STUDIO®.
Read full article..