Non-destructive testing example : Coil above a crack
The structure consists of a block of austenitic stainless steel which contains a rectangular slot, representing a flaw (see Fig. 1). A differential probe moves across the surface of the block. The probe is a cylinder with an inducing solenoid 44 mm in diameter and two smaller receptive solenoids 10 mm in diameter. Each of these two solenoids is placed in a branch of a Wheatstone's bridge. Therefore, the measured voltage signal is proportional to the difference of the magnetic fluxes in the two receiver solenoids.
Figure 1: Structure geometry
Since the benchmark requires results for various relative positions of the coil and crack, the x and y coordinates of the crack were parameterized.
The excitation coil was defined by using the "coil" feature of CST EMS. The receiving coils do not need to be modelled as 3D objects. Instead, the magnetic fluxes at the locations of the receiving coils are calculated in the postprocessing phase.
Since the signal which needs to be detected is very small, it can be affected by large numerical errors. In order to avoid this, the "perturbation" flux in each receiving coil was calculated, by computing the difference between the the magnetic fluxes with and without a crack. The corresponding magnetic flux densities are shown in Figures 2-4.
Figure 2: Magnetic flux without crack
Figure 3: Magnetic field in the presence of the crack
Figure 4: "Perturbation" magnetic field
The difference of the perturbation magnetic fluxes in the two receiving coils, for different positions of the crack, was computed.
The signal trajectory in the Real-Imaginary plane, for a coil placed 28 mm above the plate and moved parallel to the crack is plotted in Figure 5, showing a good agreement with the measured results (Figure 6).
Figure 5: Simulated signal trajectory, motion parallel to the flow (coil position 28 mm above the plate)
Figure 6: Measured trajectory, motion parallel to the flow
CST Article "Non-destructive testing example : Coil above a crack"
last modified 5. Nov 2008 5:43
printed 6. Jan 2009 9:21, Article ID 117
URL:
All rights reserved.
Without prior written permission of CST, no part of this publication may be
reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.
Article ID: 117
Last modified: 5. Nov 2008 5:43
Other Articles
A UWB dipole antenna composed of circular arms containing a special feeding system is modeled simulated using CST MICROWAVE STUDIO®, the results of which are presented in this article. The design, developed by IETR-INSA / Thomson R&D France, shows good broadband matching (3-10 GHz) and an omnidiectional radiation pattern up to 6 GHz.
Read full article..
CST EM STUDIO™ can be used to obtain the force-current characteristics of a magnetic brake. The Magnetostatic Solver is ideal for such an application.
Read full article..
Transmitters used in vehicle environments present potential threats to the health and safety of vehicle users, in terms of both human exposure to electromagnetic fields and vehicle EMC (electromagnetic compatibility). The recently revised automotive EMC directive (2004/104/EC) now requires vehicle manufacturers to identify acceptable frequencies, powers and antenna installations that can be used on vehicles without compromising their EMC performance.
The simulations presented here were performed with CST MICROSTRIPES™.
Read full article..
The unique network co-simulation feature in CST STUDIO SUITE™ 2009 enables a direct transient simulation of a 3D CST MICROWAVE STUDIO® (CST MWS) structure with non-linear lumped components or circuit networks in CST DESIGN STUDIO™ (CST DS).
This article shows the application of this feature to the simulation of a Step Recovery Diode (SRD) pulse generator.
Read full article..
This article shows how the wake field solver of CST PARTICLE STUDIO™ can be used to simulate a beam position monitor in the pick-up mode. The used beam position monitor is a quarter wavelength electrode similar to the one used in the Electron Storage Ring (ESR) of the Gesellschaft für Schwerionenforschung (GSI) Darmstadt.
Read full article..