TEAM Benchmark 8 - Non-destructive testing example : Coil above a crack

The structure consists of a block of austenitic stainless steel which contains a rectangular slot, representing a flaw (see Fig. 1). A differential probe moves across the surface of the block. The probe is a cylinder with an inducing solenoid 44 mm in diameter and two smaller receptive solenoids 10 mm in diameter. Each of these two solenoids is placed in a branch of a Wheatstone's bridge. Therefore, the measured voltage signal is proportional to the difference of the magnetic fluxes in the two receiver solenoids.


Structure geometry
Figure 1: Structure geometry

Since the benchmark requires results for various relative positions of the coil and crack, the x and y coordinates of the crack were parameterized.

The excitation coil was defined by using the "coil" feature of CST EMS. The receiving coils do not need to be modelled as 3D objects. Instead, the magnetic fluxes at the locations of the receiving coils are calculated in the postprocessing phase.

Since the signal which needs to be detected is very small, it can be affected by large numerical errors. In order to avoid this, the "perturbation" flux in each receiving coil was calculated, by computing the difference between the the magnetic fluxes with and without a crack. The corresponding magnetic flux densities are shown in Figures 2-4.


Magnetic flux without crack
Figure 2: Magnetic flux without crack


Magnetic field in the presence of the crack
Figure 3: Magnetic field in the presence of the crack


"Perturbation" magnetic field
Figure 4: "Perturbation" magnetic field

The difference of the perturbation magnetic fluxes in the two receiving coils, for different positions of the crack, was computed.

The signal trajectory in the Real-Imaginary plane, for a coil placed 28 mm above the plate and moved parallel to the crack is plotted in Figure 5, showing a good agreement with the measured results (Figure 6).


Simulated signal trajectory, motion parallel to the flow (coil position 28 mm above the plate)
Figure 5: Simulated signal trajectory, motion parallel to the flow (coil position 28 mm above the plate)


Measured trajectory, motion parallel to the flow
Figure 6: Measured trajectory, motion parallel to the flow


CST Article "TEAM Benchmark 8 - Non-destructive testing example : Coil above a crack"
last modified 9. Apr 2009 11:44
printed 10. Feb 2012 10:09, Article ID 117
URL:

All rights reserved.
Without prior written permission of CST, no part of this publication may be reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.

Other Articles

Transmission Line Noise Source Simulation with CST MICROWAVE STUDIO®

Transmission Line Noise Source Simulation with CST MICROWAVE STUDIO®
This article demonstrates the simulatenous excitation of arbitrary waveforms at a number of different ports. A noise source in the form of a loop circuit is place above an IC package and the influence of the noise source on the transmission of differential signals in the IC feed tranmssion lines is investigated. Two frequency ranges were simulated, 1-10 GHz and 1-20 GHz. The simulations were carried out using the simultaneous excitation feature in CST MICROWAVE STUDIO® (CST MWS). Read full article..

Assessment of occupational exposure of MRI workers resulting from a time-varying magnetic field associated with a cylindrical z-gradient coil

Assessment of occupational exposure of MRI workers resulting from a time-varying magnetic field associated with a cylindrical z-gradient coil Document type
The exposure of staff in the vicinity of MRI scanners to low frequency (~ 1 kHz) time-varying fields associated with gradient coils is currently of interest in view of limits prescribed in the European Union Directive 2004/40/EC (1) due to be legally enforced from April 2008. Concern has been raised regarding the likely impact that exposure limits described in (1) will have on MRI practice but currently there is little information in the literature regarding such occupational exposure. In this work we address the interactions of a switched gradient magnetic field with a human body located near to a MRI scanner. Read full article..

CMOS VCSEL Driver Design using CST MICROWAVE STUDIO® and Agilent ADS

CMOS VCSEL Driver Design using CST MICROWAVE STUDIO® and Agilent ADS
CST MICROWAVE STUDIO® and Agilent ADS have been successfully employed in this OEIC driver design - an example of a high speed analog/broadband IC application.The package model was imported from Agilent momentum and the model was simulated upto a 100 GHz in CST MWS.The resulting eye diagrams of the driver design from CST MWS are compared with those from Agilent momentum and other test cases. Read full article..

Consistent Charged Particle Simulation of a Pierce Gun

Consistent Charged Particle Simulation of a Pierce Gun
The pierce type gun example demonstrates the analysis of an electrically large gun configuration using CST PARTICLE STUDIO™ Read full article..

Electron Gun for a 6-18GHz, 20W Helix-TWT Amplifier

Electron Gun for a 6-18GHz, 20W Helix-TWT Amplifier
Electron guns are the starting point of every charged particle application. There the DC energy is translated into an extracted beam which later on interacts with all kinds of RF structures. The design and analysis of an electron gun can be performed with the tracking code of CST PARTICLE STUDIO® as shown in this article. Read full article..

Back